Winsen MEu-CO Carbon Monoxide Sensor

The Winsen MEu-CO is an electrochemical (fuel-cell) carbon monoxide sensor that outputs a current proportional to CO concentration. Designed for portable CO meters and fixed CO detectors used in industrial safety and environmental monitoring.

Highlights

  • CO range: 0–1000 ppm (max 2000 ppm)
  • Sensitivity: 0.085 ± 0.015 nA/ppm
  • Fast response: T90 < 15 s
  • Low zero output and good stability
  • Typical service life: 3 years (in air)
Categories: ,

Description

MEu-CO is a fuel-cell type electrochemical sensor for carbon monoxide detection. CO and oxygen undergo redox reactions at the electrodes, generating an output current proportional to CO concentration (Faraday’s law). The sensor is suitable for integration into CO alarms, instruments, and transmitters.

Key Features

  • Excellent repeatability and stability
  • Fast response for real-time CO monitoring
  • Suitable for both portable instruments and fixed detection systems

Typical Applications

  • Industrial CO detection (petroleum, petrochemical, metallurgy, mining, etc.)
  • Environmental monitoring and safety instruments
  • Portable CO detectors and meters
  • Fixed-point CO detectors and transmitters

Technical Specifications

Item Specification
Target gas Carbon Monoxide (CO)
Sensing principle Electrochemical (fuel-cell)
Measurement range 0–1000 ppm
Maximum range 2000 ppm
Sensitivity 0.085 ± 0.015 nA/ppm
Response time (T90) < 15 s
Zero output (clean air) < ±2 ppm (CO equivalent)
Zero drift (-40 to +50 °C) < +10 ppm (CO equivalent)
Repeatability < ±3% of output value
Linearity Within ±5%
Stability (average decay/month) < 2%
Long-term drift < 5%/year
Expected service life 3 years (in air)

Operating & Storage Conditions

Item Specification
Working temperature (continuous) -20 to +40 °C
Working temperature (intermittent) -40 to +55 °C
Humidity range 15–90% RH (non-condensing)
Pressure 1 atm ±10%
Recommended storage temperature +10 to +30 °C
Storage time (original package) ≤ 6 months
Aging time before use ≥ 48 hours

Cross-Sensitivity (Typical)

Interfering Gas Test Concentration CO Equivalent Output
H₂S 100 ppm 0 ppm
SO₂ 20 ppm 0 ppm
H₂ 200 ppm 25 ppm
C₂H₄ (Ethylene) 100 ppm 100 ppm

Pinout / Electrode Definition

Pin Electrode Description
1 C Counter electrode
2 W Working electrode
3 R Reference electrode

Handling & Cautions

  • Use the manufacturer-recommended connector; do not directly solder the tube pins.
  • Allow at least 48 hours aging time before use.
  • Avoid long-term exposure to over-range high CO concentrations to prevent damage.
  • Do not disassemble the sensor (electrolyte leakage risk).
  • Avoid organic solvents, adhesives, coatings, fuels, and corrosive gas environments.
  • When not in use, short-circuit the two poles to prevent electrode polarization.

Reviews

There are no reviews yet.


Be the first to review “Winsen MEu-CO Carbon Monoxide Sensor”