G60 4-in-1 Portable Multi-Gas Detector

Portable Multi-Gas Detector · Otywell

Portable detector for selected combustible and toxic gas hazards. The manufacturer lists one-to-four-gas configurations, natural-diffusion sampling, an LCD and sound, light and vibration alarms. Sensor combinations are selected for the task.

  • Configurable 1–4 gas channels
  • Natural-diffusion sampling
  • LCD display
  • Sound, light and vibration alarms
  • On-device data storage and PC upload
  • IP66 and intrinsic-safety markings listed
Detection Gas / ParametersLEL, O2, H2S, CO, NH3
Product TypePortable Multi-Gas Detector
BrandOtywell

The installed sensor package, measurement ranges and available options depend on the ordered configuration. Confirm the final specification before application.

G60 · Portable Multi-Gas Detector

G60 4-in-1 Portable Multi-Gas Detector for Confined Space

Portable detector for selected combustible and toxic gas hazards. The manufacturer lists one-to-four-gas configurations, natural-diffusion sampling, an LCD and sound, light and vibration alarms. Sensor combinations are selected for the task.

The model should be selected against the target measurement, operating environment and required system interface. Where a product family offers multiple sensors or hardware versions, the ordered configuration—not the full option list—defines the instrument supplied.

01 / Product Highlights

Key Features

Product functions and configuration points relevant to equipment selection.

01 / PRODUCT DETAIL

Configurable 1–4 gas channels

Configurable 1–4 gas channels

02 / PRODUCT DETAIL

Natural-diffusion sampling

Natural-diffusion sampling

03 / PRODUCT DETAIL

LCD display

LCD display

04 / PRODUCT DETAIL

Sound, light and vibration alarms

Sound, light and vibration alarms

05 / PRODUCT DETAIL

On-device data storage and PC upload

On-device data storage and PC upload

06 / PRODUCT DETAIL

IP66 and intrinsic-safety markings listed

IP66 and intrinsic-safety markings listed

02 / Engineering Data

Technical Specifications

Values below are limited to information identified in supplier material. Confirm the current datasheet for the exact model revision and ordered configuration.

Parameter Specification
Sampling natural diffusion
battery 3.7 V 2400 mAh
working time ≥20 h non-alarm standby
Reference IP66
Reference Ex ia IIC T4 Ga / Ex ib IIIC T130°C Db
Reference −10 to +55°C
Reference 78 × 71.5 × 28 mm
Reference approx. 130 g

Sensor options, measuring ranges, alarm thresholds, interfaces and approvals may vary by configuration. Confirm the final specification before installation or use in a regulated environment.

03 / Measurement Configuration

Detection Gas & Measurement Parameters

The parameters below identify the product’s intended measurement scope. The actual installed channels and ranges must be confirmed for the ordered unit.

Gas / Parameter Configuration
LEL Confirm from the ordered sensor configuration
O2 Confirm from the ordered sensor configuration
H2S Confirm from the ordered sensor configuration
CO Confirm from the ordered sensor configuration
NH3 Confirm from the ordered sensor configuration

04 / Use Environments

Typical Applications

Application suitability depends on the measured hazard, instrument configuration and site requirements.

Confined Space

G60 4-in-1 Portable Multi-Gas Detector can be specified for this environment when its sensor configuration and operating limits match the site requirements.

Industrial Safety

G60 4-in-1 Portable Multi-Gas Detector can be specified for this environment when its sensor configuration and operating limits match the site requirements.

Marine

G60 4-in-1 Portable Multi-Gas Detector can be specified for this environment when its sensor configuration and operating limits match the site requirements.

05 / Equipment Selection

How to Specify the G60

Define the measurement task before choosing a product configuration.

  • Target measurement: Confirm the gas or environmental parameter and whether more than one channel is required.
  • Range and performance: Match the measuring range, resolution, accuracy and response requirements to the application.
  • Installation environment: Review temperature, humidity, dust, water exposure, mounting and hazardous-area requirements.
  • System integration: Confirm power, analog or digital outputs, communication protocol and alarm interfaces.
  • Maintenance: Check calibration, bump-test, sensor replacement and service requirements in the current manual.

06 / Common Questions

Frequently Asked Questions

What does the G60 measure?

The product information identifies LEL, O2, H2S, CO, NH3. The exact channels and ranges depend on the ordered configuration and should be confirmed against the current datasheet.

Which version of the G60 should I select?

Start with the target gas or parameter, required measuring range, installation environment and output requirements. Confirm the final sensor and hardware configuration with the supplier.

Are all listed options included in one standard unit?

No. Options shown for a model family should not be assumed to be installed simultaneously. The quotation and datasheet should identify the exact supplied configuration.

What documents should be checked before installation?

Review the current datasheet, user manual, wiring or mounting information and any certificate required for the intended site.

Related Products